Ballu Error Codes

Every Ballu error code we have catalogued, with what it means on site — 29 codes in total. In R-Pro, tap any code to get the meaning, likely causes and inspection steps, even with no signal in the plant room.

29 codes

Common Ballu codes

CodeWhat it means
E1Internal temp sensor malfunction/short
E2External temp sensor malfunction/short
E3Condenser temp sensor malfunction/short
E4Evaporator temp sensor malfunction/short
E5System protection / outdoor fault
E6Outdoor protection tripped / indoor fan fault
E8Electrostatic filter error
P4Evaporator sensor / compressor disabled
P5Capacitor sensor malfunction / temp fluctuation
P6Heat exchanger frozen / defrosting
01 (Indoor)Indoor: room temp sensor fault
02 (Indoor)Indoor: HX temp sensor fault
03 (Indoor)Indoor: HX frozen/icing
04 (Indoor)Indoor: HX temp exceeds limit
05 (Indoor)Indoor: communication interrupted
08 (Indoor)Indoor: fan motor defective
01 (Outdoor)Outdoor: ambient sensor fault
02 (Outdoor)Outdoor: HX temp sensor fault
03 (Outdoor)Outdoor: compressor overheat/overload
04 (Outdoor)Outdoor: capillary A sensor fault
05 (Outdoor)Outdoor: capillary B sensor fault
06 (Outdoor)Outdoor: overcurrent protection
07 (Outdoor)Outdoor: no load / compressor disconnected
08 (Outdoor)Outdoor: abnormal voltage
09 (Outdoor)Outdoor: instant power interruption
10 (Outdoor)Outdoor: overloading during cooling
11 (Outdoor)Outdoor: defrost in process
12 (Outdoor)Outdoor: IPM module defective
13 (Outdoor)Outdoor: EEPROM corrupted

Official Ballu source / manual ↗

Frequently asked

What does Ballu error code E1 mean?

Ballu error code E1 means: Internal temp sensor malfunction/short. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Ballu error code E2 mean?

Ballu error code E2 means: External temp sensor malfunction/short. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Ballu error code E3 mean?

Ballu error code E3 means: Condenser temp sensor malfunction/short. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Ballu error code E4 mean?

Ballu error code E4 means: Evaporator temp sensor malfunction/short. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Ballu error code E5 mean?

Ballu error code E5 means: System protection / outdoor fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Ballu error code E6 mean?

Ballu error code E6 means: Outdoor protection tripped / indoor fan fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Ballu error code E8 mean?

Ballu error code E8 means: Electrostatic filter error. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Ballu error code P4 mean?

Ballu error code P4 means: Evaporator sensor / compressor disabled. In R-Pro you also get the likely causes and the inspection steps — offline.