Beko Error Codes

Every Beko error code we have catalogued, with what it means on site — 30 codes in total. In R-Pro, tap any code to get the meaning, likely causes and inspection steps, even with no signal in the plant room.

30 codes

Common Beko codes

CodeWhat it means
E1Indoor unit temp sensor fault
E2Evaporator coil sensor fault
E3Compressor desync/overload
E4Compressor discharge sensor fault
E5Indoor/outdoor comm error
1EOutdoor air sensor fault
2ECondenser temp sensor fault
ECRefrigerant leakage detection
EEEEPROM parameter error
Ff01Indoor room sensor malfunction
Ff02Indoor coil sensor malfunction
Ff03Condenser temp rise (cooling)
Ff04Condenser temp rise (heating)
Ff05Outdoor exhaust sensor fault
Ff06Indoor fan motor issue
Ff07Room sensor fault (alternative)
Ff08Evaporator sensor fault (alternative)
Ff09Defrost sensor fault
F1Indoor ambient sensor short/open
F2Evaporator sensor short/open
F3Outdoor ambient sensor short/open
F4Condenser sensor short/open
P4Inverter compressor drive error
P5System overcurrent protection
EdOutdoor general fault lockout
H1Auto-defrost mode (normal)
H6Indoor fan motor no feedback
U8PG fan zero-crossing error
C5Jumper cap malfunction/missing
L1Low voltage protection

Official Beko source / manual ↗

Frequently asked

What does Beko error code E1 mean?

Beko error code E1 means: Indoor unit temp sensor fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Beko error code E2 mean?

Beko error code E2 means: Evaporator coil sensor fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Beko error code E3 mean?

Beko error code E3 means: Compressor desync/overload. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Beko error code E4 mean?

Beko error code E4 means: Compressor discharge sensor fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Beko error code E5 mean?

Beko error code E5 means: Indoor/outdoor comm error. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Beko error code 1E mean?

Beko error code 1E means: Outdoor air sensor fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Beko error code 2E mean?

Beko error code 2E means: Condenser temp sensor fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Beko error code EC mean?

Beko error code EC means: Refrigerant leakage detection. In R-Pro you also get the likely causes and the inspection steps — offline.