Carrier Error Codes

Every Carrier error code we have catalogued, with what it means on site — 37 codes in total. In R-Pro, tap any code to get the meaning, likely causes and inspection steps, even with no signal in the plant room.

37 codes

Common Carrier codes

CodeWhat it means
E0Indoor EEPROM parameter error
E1Indoor/outdoor communication error
E2Zero-crossing signal error
E3Indoor fan speed out of control
E4Indoor temp sensor T1 open/short
E5Evaporator coil sensor T2 open/short
E6Room or evaporator coil sensor open/short
E7Outdoor fan speed out of control
E8System overload protection
ECRefrigerant leakage detection
EEMemory card error
F0Pump down mode
F1Outdoor ambient sensor T4 open/short
F2Condenser coil sensor T3 open/short
F3Compressor discharge sensor T5 open/short
F4Outdoor EEPROM parameter error
F5Outdoor fan speed out of control
H1Defrost / heating oil return cycle
H3Compressor overheat protection
H5IPM protection
HCPFC protection malfunction
LCCompressor start-up failure
LDCompressor phase loss protection
LECompressor stalling
LPIndoor/outdoor units mismatch
P0IPM malfunction / IGBT overcurrent
P1Over/under voltage protection
P2Compressor top high temp protection
P4Inverter compressor drive error
P5Compressor current protection
P6Inverter drive ↔ main board comm error
P7Heat sink temp sensor malfunction
P8IPM over-temperature protection
PHHigh voltage protection
PLLow voltage protection
U1Compressor phase detection malfunction
U3Low DC bus voltage

Official Carrier source / manual ↗

Frequently asked

What does Carrier error code E0 mean?

Carrier error code E0 means: Indoor EEPROM parameter error. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Carrier error code E1 mean?

Carrier error code E1 means: Indoor/outdoor communication error. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Carrier error code E2 mean?

Carrier error code E2 means: Zero-crossing signal error. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Carrier error code E3 mean?

Carrier error code E3 means: Indoor fan speed out of control. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Carrier error code E4 mean?

Carrier error code E4 means: Indoor temp sensor T1 open/short. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Carrier error code E5 mean?

Carrier error code E5 means: Evaporator coil sensor T2 open/short. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Carrier error code E6 mean?

Carrier error code E6 means: Room or evaporator coil sensor open/short. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Carrier error code E7 mean?

Carrier error code E7 means: Outdoor fan speed out of control. In R-Pro you also get the likely causes and the inspection steps — offline.