Dantex Error Codes
Every Dantex error code we have catalogued, with what it means on site — 26 codes in total. In R-Pro, tap any code to get the meaning, likely causes and inspection steps, even with no signal in the plant room.
Common Dantex codes
| Code | What it means |
|---|---|
| E2 | Frost protection mode |
| E4 | High outlet temp protection |
| E5 | Overcurrent protection |
| EE | Microcontroller memory / control board error |
| ED | Communication issue between units |
| F0 | Low refrigerant detection |
| F1 | Indoor ambient temp sensor open/short |
| F2 | Indoor coil temp sensor open/short |
| F3 | Outdoor ambient temp sensor open/short |
| F4 | Outdoor coil temp sensor open/short |
| F5 | Outdoor discharge sensor open/short |
| H3 | Compressor overload protection |
| H4 | System overloading / dirty coils |
| H6 | No feedback from indoor motor |
| H7 | Compressor desynchronization |
| P4 | Indoor overcurrent protection |
| P5 | Outdoor overcurrent protection |
| P7 | Module temp sensor open/short |
| P8 | IPM module high temp protection |
| U1 | Phase current detection issue |
| U5 | Fault direction of current |
| U7 | 4-way valve issue |
| UF | Zero crossing malfunction |
| UH | No feedback from outdoor motor |
| UU | DC overloading phase |
| LC | Startup failure |
Official Dantex source / manual ↗
Frequently asked
What does Dantex error code E2 mean?
Dantex error code E2 means: Frost protection mode. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Dantex error code E4 mean?
Dantex error code E4 means: High outlet temp protection. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Dantex error code E5 mean?
Dantex error code E5 means: Overcurrent protection. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Dantex error code EE mean?
Dantex error code EE means: Microcontroller memory / control board error. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Dantex error code ED mean?
Dantex error code ED means: Communication issue between units. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Dantex error code F0 mean?
Dantex error code F0 means: Low refrigerant detection. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Dantex error code F1 mean?
Dantex error code F1 means: Indoor ambient temp sensor open/short. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Dantex error code F2 mean?
Dantex error code F2 means: Indoor coil temp sensor open/short. In R-Pro you also get the likely causes and the inspection steps — offline.
Look up any error code — offline — in R-Pro.
Open R-Pro →