Derby Error Codes

Every Derby error code we have catalogued, with what it means on site — 31 codes in total. In R-Pro, tap any code to get the meaning, likely causes and inspection steps, even with no signal in the plant room.

31 codes

Common Derby codes

CodeWhat it means
E0EEPROM malfunction / memory corruption
E1Indoor/outdoor communication failure
E2Power supply voltage fluctuation/failure
E3Indoor/outdoor fan speed control issue
E4System abnormality / compressor protection
E5Outdoor temp sensor malfunction
E6Indoor fan motor / temp sensor fault
E7Outdoor ambient temp sensor fault
E8Discharge temp sensor fault
E9Inverter module / IPM protection warning
ECRefrigerant leakage detection
EEEEPROM error / memory loss
F1Outdoor DC fan motor fault
F2Compressor starting failure
F3Compressor loss of synchronism
F4Exhaust temp overheat protection
F5Compressor top cover protection
F6Outdoor EEPROM fault
F7Voltage protection (over/under)
F8Outdoor main board failure
F9PFC protection / inverter fault
P0IPM module overcurrent
P1Over/under voltage lockout
P2Compressor top temp protection
P3Outdoor low temp protection
P4Compressor drive error (inverter)
P5Mode conflict (multi-split)
P6Compressor low-pressure protection
P7Outdoor IGBT temp sensor error
H1Auto-defrost mode (normal)
H3Compressor overload protection

Official Derby source / manual ↗

Frequently asked

What does Derby error code E0 mean?

Derby error code E0 means: EEPROM malfunction / memory corruption. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Derby error code E1 mean?

Derby error code E1 means: Indoor/outdoor communication failure. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Derby error code E2 mean?

Derby error code E2 means: Power supply voltage fluctuation/failure. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Derby error code E3 mean?

Derby error code E3 means: Indoor/outdoor fan speed control issue. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Derby error code E4 mean?

Derby error code E4 means: System abnormality / compressor protection. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Derby error code E5 mean?

Derby error code E5 means: Outdoor temp sensor malfunction. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Derby error code E6 mean?

Derby error code E6 means: Indoor fan motor / temp sensor fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Derby error code E7 mean?

Derby error code E7 means: Outdoor ambient temp sensor fault. In R-Pro you also get the likely causes and the inspection steps — offline.

Look up any error code — offline — in R-Pro.

Open R-Pro →