Hisense Error Codes
Every Hisense error code we have catalogued, with what it means on site — 29 codes in total. In R-Pro, tap any code to get the meaning, likely causes and inspection steps, even with no signal in the plant room.
Common Hisense codes
| Code | What it means |
|---|---|
| 01 | Outdoor EEPROM parameter error |
| 02 | Compressor start failure |
| 11 | Indoor EEPROM error |
| 13 | Indoor fan motor defect |
| 14 | Outdoor DC fan motor defect |
| 33 | Compressor discharge temp too high |
| 34 | Compressor AC over-current |
| 36 | Communication fault (indoor↔outdoor) |
| 38 | Outdoor PCB / EEPROM fault |
| 39 | Compressor motor phase loss |
| 41 | IPM protection |
| 43 | PFC protection |
| E1 | Room temperature sensor error |
| E2 | Indoor coil temp sensor error |
| E3 | Outdoor coil temp sensor error |
| E4 | Outdoor ambient temp sensor error |
| E5 | Compressor discharge sensor error |
| E6 | Indoor/outdoor communication error |
| E8 | Indoor fan motor error |
| E9 | Outdoor fan motor error |
| EA | Current sensor / wiring error |
| EE | EEPROM malfunction |
| F1 | IPM over-current protection |
| F2 | IPM overheating protection |
| F3 | Compressor drive error |
| F4 | System refrigerant leak detection |
| F5 | High pressure protection limit |
| F6 | Low pressure protection limit |
| FE | Voltage over/under protection |
Official Hisense source / manual ↗
Frequently asked
What does Hisense error code 01 mean?
Hisense error code 01 means: Outdoor EEPROM parameter error. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Hisense error code 02 mean?
Hisense error code 02 means: Compressor start failure. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Hisense error code 11 mean?
Hisense error code 11 means: Indoor EEPROM error. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Hisense error code 13 mean?
Hisense error code 13 means: Indoor fan motor defect. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Hisense error code 14 mean?
Hisense error code 14 means: Outdoor DC fan motor defect. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Hisense error code 33 mean?
Hisense error code 33 means: Compressor discharge temp too high. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Hisense error code 34 mean?
Hisense error code 34 means: Compressor AC over-current. In R-Pro you also get the likely causes and the inspection steps — offline.
What does Hisense error code 36 mean?
Hisense error code 36 means: Communication fault (indoor↔outdoor). In R-Pro you also get the likely causes and the inspection steps — offline.