Kelvinator Error Codes

Every Kelvinator error code we have catalogued, with what it means on site — 32 codes in total. In R-Pro, tap any code to get the meaning, likely causes and inspection steps, even with no signal in the plant room.

32 codes

Common Kelvinator codes

CodeWhat it means
C5Jumper cap malfunction
D1DRED (compressor off)
D2DRED (output -50%)
D3DRED (output -75%)
E2Anti-freeze protection
E3Gas leak or refrigeration blockage
E4Compressor high-temperature protection
E5AC overcurrent protection
E6Communication fault
E8Anti-high temperature protection
EEEEPROM malfunction
F1Indoor room temperature sensor failure
F2Indoor tube temperature sensor failure
F3Outdoor ambient sensor failure
F4Outdoor coil sensor failure
F5Outdoor compressor discharge sensor failure
F6Anti-high temperature protection
FHFrequency drop / anti-freeze limit
H1Defrosting mode
H3Compressor overload protection
H5IPM protection
H6Indoor fan motor stall
HCPFC protection
L3Outdoor DC fan motor malfunction
LPIndoor/outdoor unit mismatch
P1Compressor rated frequency test
P2Compressor maximum frequency test
P3Compressor medium frequency test
PHHigh voltage protection
PLLow voltage protection
POCompressor minimum frequency test
U74-way valve problem

Official Kelvinator source / manual ↗

Frequently asked

What does Kelvinator error code C5 mean?

Kelvinator error code C5 means: Jumper cap malfunction. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Kelvinator error code D1 mean?

Kelvinator error code D1 means: DRED (compressor off). In R-Pro you also get the likely causes and the inspection steps — offline.

What does Kelvinator error code D2 mean?

Kelvinator error code D2 means: DRED (output -50%). In R-Pro you also get the likely causes and the inspection steps — offline.

What does Kelvinator error code D3 mean?

Kelvinator error code D3 means: DRED (output -75%). In R-Pro you also get the likely causes and the inspection steps — offline.

What does Kelvinator error code E2 mean?

Kelvinator error code E2 means: Anti-freeze protection. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Kelvinator error code E3 mean?

Kelvinator error code E3 means: Gas leak or refrigeration blockage. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Kelvinator error code E4 mean?

Kelvinator error code E4 means: Compressor high-temperature protection. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Kelvinator error code E5 mean?

Kelvinator error code E5 means: AC overcurrent protection. In R-Pro you also get the likely causes and the inspection steps — offline.

Look up any error code — offline — in R-Pro.

Open R-Pro →