Mitsubishi Electric Error Codes

Every Mitsubishi Electric error code we have catalogued, with what it means on site — 38 codes in total. In R-Pro, tap any code to get the meaning, likely causes and inspection steps, even with no signal in the plant room.

38 codes

Common Mitsubishi Electric codes

CodeWhat it means
A0Duplicate address (Lossnay same address)
A2Transmission processor hardware error (Lossnay)
A3Line busy, no data for 8 minutes
A6Communication error with communication processor
A7No ACK signal
A8M-Net no response
EAMis-wiring / loose cables / noise interference
EBMis-wiring / noise / wrong cable spec
ECStart-up time over (failed to initialise)
EDSerial communication error
E0Remote controller communication error
E1Remote controller issue
E3Remote controller not transmitting
E4Remote controller not receiving
E6Indoor/outdoor communication error
E7Comms fault between indoor and outdoor
E8Comms failure indoor↔outdoor (S2/S3)
F1Reverse phase detection
F2L3 phase open
F363L (low pressure switch) open
F563H (high pressure switch) open
F7Phase detection circuit fault
F8No input detected at outdoor unit
F9Two or more protection devices open
P1Return air thermistor fault (TH1)
P2Liquid pipe thermistor fault (TH2)
P4Drain sensor fault
P5High condensate level
P6Indoor heat exchanger freezing/overheating
P8Abnormal pipe temperature
P9TH5 condenser/evaporator thermistor open/short
U1High pressure trip
U2High discharge temperature
U3Discharge thermistor fault
U4Outdoor thermistor fault
U5Inverter heat sink temperature too high (TH8)
U6Compressor over-current
U7Low discharge superheat

Official Mitsubishi Electric source / manual ↗

Frequently asked

What does Mitsubishi Electric error code A0 mean?

Mitsubishi Electric error code A0 means: Duplicate address (Lossnay same address). In R-Pro you also get the likely causes and the inspection steps — offline.

What does Mitsubishi Electric error code A2 mean?

Mitsubishi Electric error code A2 means: Transmission processor hardware error (Lossnay). In R-Pro you also get the likely causes and the inspection steps — offline.

What does Mitsubishi Electric error code A3 mean?

Mitsubishi Electric error code A3 means: Line busy, no data for 8 minutes. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Mitsubishi Electric error code A6 mean?

Mitsubishi Electric error code A6 means: Communication error with communication processor. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Mitsubishi Electric error code A7 mean?

Mitsubishi Electric error code A7 means: No ACK signal. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Mitsubishi Electric error code A8 mean?

Mitsubishi Electric error code A8 means: M-Net no response. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Mitsubishi Electric error code EA mean?

Mitsubishi Electric error code EA means: Mis-wiring / loose cables / noise interference. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Mitsubishi Electric error code EB mean?

Mitsubishi Electric error code EB means: Mis-wiring / noise / wrong cable spec. In R-Pro you also get the likely causes and the inspection steps — offline.