Winia (Daewoo) Error Codes

Every Winia (Daewoo) error code we have catalogued, with what it means on site — 20 codes in total. In R-Pro, tap any code to get the meaning, likely causes and inspection steps, even with no signal in the plant room.

20 codes

Common Winia (Daewoo) codes

CodeWhat it means
E0 (Indoor)Indoor EEPROM chip error / corrupted data
E1 (Indoor)Indoor–outdoor communication fault
E2 (Indoor)Zero-crossing detection error
E3 (Indoor)Fan speed abnormality
E6 (Indoor)Room temperature sensor malfunction
E0 (Outdoor)Outdoor EEPROM chip error / corrupted data
E1 (Outdoor)Pipe temperature sensor 1 fault
E2 (Outdoor)Pipe temperature sensor 2 fault
E3 (Outdoor)Pipe temperature sensor 3 fault
E4 (Outdoor)Outdoor ambient temperature sensor fault
E5 (Outdoor)Over/under voltage protection
E6 (Outdoor)Indoor pipe temperature sensor malfunction
E7 (Outdoor)Indoor–outdoor communication failure
P0IPM module defect / protection
P1High-pressure protection
P2Compressor temperature protection
P3Compressor current protection
P4Inverter module protection
P5Outdoor low-temperature protection
P6Condenser overheating protection

Official Winia (Daewoo) source / manual ↗

Frequently asked

What does Winia (Daewoo) error code E0 (Indoor) mean?

Winia (Daewoo) error code E0 (Indoor) means: Indoor EEPROM chip error / corrupted data. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Winia (Daewoo) error code E1 (Indoor) mean?

Winia (Daewoo) error code E1 (Indoor) means: Indoor–outdoor communication fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Winia (Daewoo) error code E2 (Indoor) mean?

Winia (Daewoo) error code E2 (Indoor) means: Zero-crossing detection error. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Winia (Daewoo) error code E3 (Indoor) mean?

Winia (Daewoo) error code E3 (Indoor) means: Fan speed abnormality. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Winia (Daewoo) error code E6 (Indoor) mean?

Winia (Daewoo) error code E6 (Indoor) means: Room temperature sensor malfunction. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Winia (Daewoo) error code E0 (Outdoor) mean?

Winia (Daewoo) error code E0 (Outdoor) means: Outdoor EEPROM chip error / corrupted data. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Winia (Daewoo) error code E1 (Outdoor) mean?

Winia (Daewoo) error code E1 (Outdoor) means: Pipe temperature sensor 1 fault. In R-Pro you also get the likely causes and the inspection steps — offline.

What does Winia (Daewoo) error code E2 (Outdoor) mean?

Winia (Daewoo) error code E2 (Outdoor) means: Pipe temperature sensor 2 fault. In R-Pro you also get the likely causes and the inspection steps — offline.