R‑ProGet the app

Refrigerant PT Chart Calculator

Convert pressure ↔ saturation temperature for 34 refrigerants. Enter a gauge reading to get the saturation temperature you need for superheat and subcooling — instantly, offline, no sign-up.

—
Enter a pressure or temperature above.

Get the full PT chart — plus diagnosis, on your phone

R-Pro carries all 34 refrigerant PT charts offline, with superheat/subcooling helpers, AI fault diagnosis, voice memo and job tracking — in 10 languages, working with no signal on site.

Start a free tier →

How to use this PT chart

Superheat & subcooling, quickly

Superheat = suction-line temperature − saturation temperature at suction pressure. Subcooling = saturation temperature at discharge/liquid pressure − liquid-line temperature. Use this tool to get the two saturation temperatures, then subtract.

Refrigerants covered

R-22, R-410A, R-404A, R-134a, R-32, R-507A, R-407C, R-600a, R-290, R-717, R-744, R-11, R-12, R-113, R-114, R-115, R-123, R-124, R-141b, R-142b, R-23, R-125, R-143a, R-152a, R-161, R-1234yf, R-1234ze(E), R-1233zd(E), R-1270, R-401A, R-422D, R-452A, R-454B, R-513A.

Values are saturation (bubble-point) data interpolated from NIST WebBook for pure refrigerants and ASHRAE approximations for blends. Use the manufacturer chart for safety-critical work.

FAQ

What is a refrigerant PT (pressure–temperature) chart?

A PT chart shows the saturated pressure of a refrigerant at a given temperature (and vice versa). Techs use it to find the saturation temperature from a gauge reading — the basis for measuring superheat and subcooling.

How do I find superheat with a PT chart?

Read the low-side (suction) pressure, convert it to saturation temperature using the PT chart for your refrigerant, then subtract that from the measured suction-line temperature. The difference is the superheat.

Which refrigerants are supported?

This tool covers 34 refrigerants including R-22, R-410A, R-404A, R-134a, R-32, R-507A, R-407C, R-600a and more — HCFC, HFC, HFO, natural and blended refrigerants.

Is this PT calculator free?

Yes. It is completely free, works offline once loaded, and needs no sign-up. The full R-Pro field app adds AI diagnosis, voice memo, equipment scan and job tracking.