Bird Nest / Wasp Nest in Outdoor Unit — Safe Removal & Prevention

Likely causes

Vent blocked / fan damaged / electrical damage

Check: Korea common May-Sep (swallows, sparrows, wasps). Symptoms: ① abnormal noise/odor. ② HP trip (airflow blocked). ③ Fan blade tangled with nest feathers/cracked. ④ PCB corroded by bird droppings (acidic). Check: power OFF, remove grill, inspect inside. Wasp nest: grey paper-like, small hole, buzzing inside.

What to do: **Bird nest**: Korean Wildlife Act protects swallows/sparrows. If eggs/chicks present, wait for fledging. Remove empty nest only, then clean/disinfect grill. **Wasps**: call 119 (free fire dept). Don't DIY/spray near PCB (fire risk). **Prevention**: grill mesh (≤5mm, not airflow blocking), reflective tape, sound deterrent device.

Field tip

Rooftop outdoor = 80% bird nests. Quote separate mesh grill install (₩50-100k, saves yearly cleaning). 119 free (human threat). City health office handles wasp safe removal. PCB bird-droppings corrosion: disassemble outer grill, blow compressed air + anhydrous alcohol clean.