Inverter Malfunction from Unstable Supply Voltage

Likely causes

Voltage drop during startup from undersized wiring

Check: Measure voltage both during run and at startup (large gap = wiring issue)

What to do: Measure voltage both during run and at startup (large gap = wiring issue) → Tighten compressor terminal screws and check contacts → Verify wire gauge and length (account for inrush current) → Disconnect other equipment from the circuit and retest → If voltage instability persists, contact utility or licensed electrician

Voltage variation from poor terminal contact

Check: Tighten compressor terminal screws and check contacts

What to do: Tighten compressor terminal screws and check contacts → Verify wire gauge and length (account for inrush current) → Disconnect other equipment from the circuit and retest → If voltage instability persists, contact utility or licensed electrician

Interference from other equipment on the same circuit

Check: Verify wire gauge and length (account for inrush current)

What to do: Verify wire gauge and length (account for inrush current) → Disconnect other equipment from the circuit and retest → If voltage instability persists, contact utility or licensed electrician

Field tip

Unstable supply voltage causes inverter malfunction or protective shutdown. Check power quality. For 3-phase inverters, phase loss causes immediate protective shutdown. Always measure all three phase voltages.