Inverter Overheating from Fouled Heat Sink

Likely causes

Cooling fin blocked by dust and debris

Check: Cut power and remove inverter cover

What to do: Cut power and remove inverter cover → Clean heat sink fins with compressed air → Check cooling fan operation and noise (replace if faulty) → Confirm at least 10 cm clearance around inverter → Restart after cleaning and confirm temperature normalizes

Cooling fan failure reducing airflow

Check: Clean heat sink fins with compressed air

What to do: Clean heat sink fins with compressed air → Check cooling fan operation and noise (replace if faulty) → Confirm at least 10 cm clearance around inverter → Restart after cleaning and confirm temperature normalizes

Poor ventilation at inverter installation location

Check: Check cooling fan operation and noise (replace if faulty)

What to do: Check cooling fan operation and noise (replace if faulty) → Confirm at least 10 cm clearance around inverter → Restart after cleaning and confirm temperature normalizes

Field tip

Dust accumulation on the inverter heat sink is causing poor cooling. Cleaning will provide immediate improvement. High-voltage sections inside the inverter require 10+ minutes after power-off to be safe to touch.