Wi-Fi Remote App Connection Failure — smartphone app cannot find AC unit

Likely causes

Connecting to 5 GHz band — AC Wi-Fi module supports 2.4 GHz only

Check: Check current connection band in phone Wi-Fi settings — if connected to 5 GHz (shows 5G), AC app cannot discover unit. Verify band settings in router admin page

What to do: Create separate 2.4 GHz-only SSID on router → connect phone to 2.4 GHz SSID → retry app connection

Router AP isolation (Client Isolation) enabled — blocks device-to-device communication

Check: Access router admin page (192.168.0.1 or 192.168.1.1) → Wireless settings → check AP Isolation / Client Isolation setting

What to do: Set AP Isolation to OFF → save → restart router → retry app connection

WPA3-only security — older AC Wi-Fi module does not support WPA3

Check: Check router security mode — if WPA3-only, compatibility issues arise. Check supported security modes in AC Wi-Fi module spec sheet

What to do: Change router security to WPA2 (AES) or WPA2/WPA3 mixed mode → save and reconnect

Field tip

Connect smartphone to 2.4 GHz SSID first, then launch app — resolves 80% of band mismatch issues. Try this first.