R-ProField casesTransport refrigeration

Cargo Box Insulation Degradation — K-value Rise

Likely causes

Polyurethane foam moisture absorption — increased thermal conductivity

Check: Measure inner/outer wall temperature differential and calculate actual K-value — consider replacement if 20%+ above design; suspect moisture if floor interior is 5°C+ above ambient

What to do: Re-seal all panel joints and corners with silicone or butyl tape → identify damaged panels with thermal imaging camera and replace partially → clean floor drains

Panel joint seal failure — water ingress

Check: Visually inspect all panel joints — check for silicone cracking, detachment, or discoloration

What to do: Remove existing sealant, apply primer → fill with new silicone → waterproofing test after 24-hour cure

Long-term aging or physical impact damage to insulation

Check: Cargo box 10+ years old or vehicle with collision history — scan all panel temperature distribution with infrared thermal camera

What to do: If full replacement not feasible, reinforce with reflective insulation sheets (aluminum) inside → partially replace damaged sections → re-measure K-value to verify effect

Field tip

Run empty box for 1 hour, then shoot exterior skin temperature with infrared camera — temperature blotches indicate areas of moisture absorption or damage.

All 565 cases work offline in R-Pro, with error codes for 62 brands and P-T data for 108 refrigerants.

Open R-Pro →

Related cases