Defrost Timer / Controller Failure

Likely causes

Defrost timer motor failure or gear damage

Check: Mechanical timer: manually advance to defrost position; heater activating = timer faulty

What to do: Mechanical timer: manually advance to defrost position; heater activating = timer faulty → Electronic: force defrost cycle and check if heater activates → Measure defrost termination sensor (bimetal/NTC) resistance → Replace timer or controller with same spec → Verify defrost cycle and heater operation after replacement

Electronic defrost controller PCB failure

Check: Electronic: force defrost cycle and check if heater activates

What to do: Electronic: force defrost cycle and check if heater activates → Measure defrost termination sensor (bimetal/NTC) resistance → Replace timer or controller with same spec → Verify defrost cycle and heater operation after replacement

Temperature sensor (defrost termination) failure

Check: Measure defrost termination sensor (bimetal/NTC) resistance

What to do: Measure defrost termination sensor (bimetal/NTC) resistance → Replace timer or controller with same spec → Verify defrost cycle and heater operation after replacement

Field tip

The defrost timer or controller is not executing defrost cycles normally. Replace it.