Excessive Condensation from Not Using Night Cover
Likely causes
Night cover not used — direct high-humidity outside air infiltration
Check: Check if night cover is used after business hours — not using increases energy 30~40%; verify store nighttime temperature is at or below 18°C
What to do: Instruct use of night cover (immediately after closing); instruct maintaining store at +18°C at night; replace damaged cover
Store night temperature too high — dew point drops
Check: Measure store temperature after closing — should maintain below +18°C at night; condensation occurs in high-temperature + high-humidity environment
What to do: Maintain night-time cooling settings or reduce ventilation; manage to achieve indoor temperature below +18°C at night
Night cover damaged — poor sealing
Check: Visually inspect entire night cover surface — tears, separation at joints, poor bottom contact; if condensation continues after use = cover failure
What to do: Replace damaged night cover; verify bottom contact fixation (magnet or retaining pin); staff training on proper usage
Not using night cover = 30~40% energy increase + condensation — maintaining store at +18°C at night paired with night cover use is the best approach; verifying cover bottom contact is key
All 565 cases work offline in R-Pro, with error codes for 62 brands and P-T data for 108 refrigerants.
Open R-Pro →Related cases
- Aging Room Humidity Control Failure (Unable to Maintain 85~95%RH)
- Ethylene Buildup in Meal Kit/Produce Warehouse — Over-Ripening Due to Ventilation Failure
- End-Zone Temperature Rise (Uneven Cooling)
- Air Curtain Weakening
- Excessive Temperature Rise After Defrost
- Excessive Heat Load from Direct Sunlight or Lighting