Fan Motor Control Signal Failure (PCB / Relay)

Likely causes

Fan relay contact failure

Check: Check fan relay coil continuity and contact conductivity

What to do: Check fan relay coil continuity and contact conductivity → Measure voltage at PCB fan output terminal → Measure temperature sensor (NTC/PTC) resistance → Replace relay if faulty → Replace PCB if faulty

PCB fan output circuit failure

Check: Measure voltage at PCB fan output terminal

What to do: Measure voltage at PCB fan output terminal → Measure temperature sensor (NTC/PTC) resistance → Replace relay if faulty → Replace PCB if faulty

Fan signal not output from temperature sensor malfunction

Check: Measure temperature sensor (NTC/PTC) resistance

What to do: Measure temperature sensor (NTC/PTC) resistance → Replace relay if faulty → Replace PCB if faulty

Field tip

Fan motor is OK but the PCB or relay is not sending an activation signal. Inspect relay and PCB.