Premature Cutoff from Thermostat Sensor Misplacement

Likely causes

Sensing bulb in direct contact with evaporator coil or frost

Check: Separate sensor bulb from coil

What to do: Separate sensor bulb from coil → Reposition in area of good air circulation inside cabinet → Check clip and insulation condition → Verify thermostat operation after reinstallation

Sensing bulb position changed from loose clip

Check: Reposition in area of good air circulation inside cabinet

What to do: Reposition in area of good air circulation inside cabinet → Check clip and insulation condition → Verify thermostat operation after reinstallation

Field tip

The sensor is directly touching the coil, sensing much lower temperatures than the actual cabinet. Relocate the sensor.