R-Pro › Field cases › Refrigeration systems

Premature Cutoff from Thermostat Sensor Misplacement

Likely causes

Sensing bulb in direct contact with evaporator coil or frost

Check: Separate sensor bulb from coil

What to do: Separate sensor bulb from coil → Reposition in area of good air circulation inside cabinet → Check clip and insulation condition → Verify thermostat operation after reinstallation

Sensing bulb position changed from loose clip

Check: Reposition in area of good air circulation inside cabinet

What to do: Reposition in area of good air circulation inside cabinet → Check clip and insulation condition → Verify thermostat operation after reinstallation

Field tip

The sensor is directly touching the coil, sensing much lower temperatures than the actual cabinet. Relocate the sensor.

All 565 cases work offline in R-Pro, with error codes for 62 brands and P-T data for 108 refrigerants.

Open R-Pro →

Related cases